• Flue Gas Treatment Qualified Incinerator for Medical Waste and Domestic Garbage
  • Flue Gas Treatment Qualified Incinerator for Medical Waste and Domestic Garbage
  • Flue Gas Treatment Qualified Incinerator for Medical Waste and Domestic Garbage
  • Flue Gas Treatment Qualified Incinerator for Medical Waste and Domestic Garbage
  • Flue Gas Treatment Qualified Incinerator for Medical Waste and Domestic Garbage
  • Flue Gas Treatment Qualified Incinerator for Medical Waste and Domestic Garbage

Flue Gas Treatment Qualified Incinerator for Medical Waste and Domestic Garbage

After-sales Service: Long Life Service
Warranty: Two Years
Condition: New
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Flue Gas Treatment Qualified Incinerator for Medical Waste and Domestic Garbage pictures & photos
Flue Gas Treatment Qualified Incinerator for Medical Waste and Domestic Garbage
US $7,000-15,000 / Set
Min. Order: 1 Set
Diamond Member Since 2024

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Shandong, China
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 30 days
Quality Assurance
The supplier provides quality assurance
Raw-Materials Traceability
The supplier has traceability identification of raw materials
to see all verified strength labels (18)

Basic Info.

Model NO.
AEH-20-40
Certification
GMA, QS, UL, FDA, ISO, CE
Automation
Automatic
Screw
Multi-Screw
Treatment
Pyrolysis
Incinerator Size(mm)
1200*1300*1800
Treatment Quantity(Kg/Batch)
20-40
Incinerator Volume(M2)
3.0
Power Consumption(Kw/H)
2-4
Oil Consumption(L/H)
3-8
Physical Weighing(T)
2.2-5.5
Transport Package
Wooden Box
Specification
5t/day
Trademark
Aoerheng
Origin
China
HS Code
8417809090
Production Capacity
50000 Sets / Year

Product Description

               Flue gas treatment qualified incinerator for medical waste and domestic garbage                                                        

1.product characteristic:

Flue Gas Treatment Qualified Incinerator for Medical Waste and Domestic Garbage
It has a wide range of treatment, which can handle most of the garbage
(household garbage, plastic garbage, wood, paper, cotton and other combustible garbage), and the final product is ceramic ash
Flue Gas Treatment Qualified Incinerator for Medical Waste and Domestic Garbage
The product can be reused, and the burnt domestic waste put into it will be turned into ceramic ash after treatment (if metal and other non-disposable waste is mixed in, it will remain in its original state and be eliminated).  
Ceramic dust can be used for construction, insulation materials, and for agricultural fertilizers.
Flue Gas Treatment Qualified Incinerator for Medical Waste and Domestic Garbage
Low operating costs.  The pyrolysis carbonization furnace draws on the theory that low-temperature magnetization technology uses magnetic motion to promote carbonization and pyrolysis, and has researched and invented a technology that can carbonize and pyrolyze garbage without using electricity, gas, oil and other high-consumption energy sources.
Flue Gas Treatment Qualified Incinerator for Medical Waste and Domestic Garbage
Environmentally friendly garbage disposal.  The carbonization pyrolysis furnace is equipped with deodorization and smoke exhaust treatment equipment.  It avoids the discharge of pollutants such as dioxins and ammonia oxides caused by garbage incineration locks.  The gas emissions are odorless and harmless, while reducing carbon dioxide emissions.

2.Introduction to grate:
 

Grate Grate support Bellows Housing Furnace wall Driving device  
The grate is arranged horizontally,which is divided into drying section,incineration section1 and incineration section 2 from front to back



 

Flue Gas Treatment Qualified Incinerator for Medical Waste and Domestic Garbage

3.product parameters:
 


Serial number
 
Specification and model Main equipment size Processing capacity
(kg/batch)
incinerator volume
(m2)
Power  consumption
(kw/h)
oil wear
(l/h)
Equipmentweight
(t)
 
        1 AEHA-25 1000*900*1700 25 2.5 2 3 1.15  
        2 AEHA-20-40 1200*1300*1800 20-40 3.0 2-4 3-8 2.2-5.5  
        3 AEHA-20-60 1700*1500*2100 20-60 5.0 2-5 3-10 4.5-7.8  
        4 AEHA-50-120 2200*2000*2500 50-120 10.0 3-12 4-15 5.0-11.5  
        5 AEHA-100-300 3000*3500*2900 100-300 13.0 10-30 10-40 15-25  
        6 AEHA-400-500 3000*3700*3200 400-500 17.0 40-50 50-60 30-45  

4.Tail gas reference standard:
The pollution control standard for hazardous waste incineration (GB18484-2001) of the State Environmental Protection Administration was implemented on January 1, 2001. The allowable concentration of pollutants discharged from flue gas is as follows:
 

number contaminants Maximum allowable emission concentration limit under different incinerator capacity(mg/m3)

       ≤300(Kg/h)                         300~2500(Kg/h                                          ≥2500(Kg/h)                                                        
 
1 Smoke blackness Ringerman level1  
2 Smoke 100                                      80                                     65  
3 Carbon monoxide 100                                      80                                     80  
4 Sulfur dioxide 400                                      300                                    200  
5 Hydrogen fluoride 9.0                                        7.0                                    5.0  
6 Hydrogen chloride 100                                        70                                    60  
7 Nitrogen oxide 0.1  
8 Mercury and its compounds 500  
9 Cadmium and its compounds 0.1  
10 Arsenic nickel and their compounds 1.0  
11 Lead and its compounds 1.0  
12 Chromium,tin,antimony,copper,manganese,and their compounds 4.0  
13 Dioxins 0.5TEQ  ng/m3  
 



5.Our transportation:
Flue Gas Treatment Qualified Incinerator for Medical Waste and Domestic GarbageFlue Gas Treatment Qualified Incinerator for Medical Waste and Domestic Garbage
6.Our factory:

AEHA series harmless incinerator is a domestic and international harmless incineration treatment equipment developed by introducing Japanese

harmless incinerator technology, organizing technical public relations, sublating the advantages and disadvantages of similar equipment at home

and abroad. The equipment has the characteristics of small volume, incineration, reasonable process, technology and high degree of

harmlessness. It is an ideal waste treatment equipment for all kinds of hospitals, hotels, stations, sanitation stations, laboratories and farms.
 

Flue Gas Treatment Qualified Incinerator for Medical Waste and Domestic Garbage   AOERHENG company covers an area of 20000 square meters. The company adopts modern enterprise management concept. seiko manufacturing. forge ahead. the product quality is superior to the domestic and foreign counterparts products.

 Company technical force is abundant. the craft is advanced. Complete range of articles. in strict accordance with ISO9001 standards. organization.design. production.sales and management.

 Company sets scientific research and development. engineering design. Installation. debugging.Production services for the integration of domestic comprehensive backbone enterprises.

Products with free-pollution disposal equipment. Garbage disposal equipment. High concentration wastewater treatment equipment. Organic fertilizer production equipment. Air treatment equipment.

Sludge treatment equipment. Automobile processing equipment such as environmental protection equipment . And can design according to customer demand.

Customization of all kinds of efficient and practical equipment and production line.


7.Our services:


pre-sale
 

1. Selection of equipment model.

2. Design and manufacture products according to the special requirements of customers.

3. The manufacturer shall send engineers and technicians to inspect the site free of charge.

sale


1. Product acceptance.

2. Assist the customer to formulate the construction scheme.

after-sales

1. Free guidance on equipment installation and commissioning

2. Train technical personnel for customers

3. On site training for operators

 




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Flue Gas Treatment Qualified Incinerator for Medical Waste and Domestic Garbage pictures & photos
Flue Gas Treatment Qualified Incinerator for Medical Waste and Domestic Garbage
US $7,000-15,000 / Set
Min. Order: 1 Set
Diamond Member Since 2024

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory
Number of Employees
8
Year of Establishment
2023-11-15